a second wrench underneath the frame.
5.1.5. Customizing the Frame
a) The standard frame, together with the adjustable angle frame kit components can be adapted to a wide
range of different installation surfaces and situations. Any modifications to the frame design must be
approved by a licensed engineer and done with structural integrity in mind, particularly in high wind areas.
󱚡 WARNING
Any modifications to the mounting frame must be approved for strength and safety by a
licensed engineer before installation.
5.1.6. Roof Attachment
a) Attachment to the roof must consider 2 key factors:
i) Strength: Attachment points must be strong enough to withstand the forces that
the collector will be exposed to, the main one being wind. This becomes very
important when the collector is installed at an angle as the exposed wind load
surface area is increased. Download force during wind, or due to snow loading
must also be considered and the weight bearing strength of the roof or structure
considered. Always select mounting methods which have suitable strength and
meet local building guidelines. If in doubt consult a licensed engineer for design
approval. Refer also to section 3.13 for estimated wind loading values.
ii) Waterproofing: The mount must not compromise the waterproof integrity of
the roof.
󱚡 WARNING
Ensure the frame attachment points and the structure to which the collector is attached are
of suitable strength. Refer to local building guidelines and consult a licensed engineer for
design approval. Failure to meet strength requirements could lead to product and property
damage and serious injury or death.
b) Refer to the following sections for more information on roof mounting options.
5.1.7. Steel Roof Mounting
a) Commercially available mounting brackets are available to mount on metal seam or corrugated iron
roofing. Apricus recommends S-5. For more information visit http://www.S-5.com
Apricus Solar Collector Installation & Operation Manual - USA
Copyright © 2011 – Apricus Inc Doc: A7-05.4.12-PB Page 35 of 129
Vista de página 37
1 2 ... 33 34 35 36 37 38 39 40 41 42 43 ... 119 120

Comentários a estes Manuais